Liquid Level Indicators

LPU-2127 Loop Powered Ultrasonic Sensor
LPU-2127 Loop Powered Ultrasonic Sensor

Integrated Keypad & Display

  • 1 to 25 ft. (0.3 to 7.6 m) measurement range
  • 1 to 10 ft. (0.3 to 3 m) detection range on granules & bulk solids
  • Class I, Div. 2, Groups C & D; Class I, Zone 2, AEx nA IIB, T6; IP65 hazardous approvals
  • Loop powered 4-20 mA
  • 2 in. NPT mounting for easy installation in tank level applications
  • Rugged PDVF (Kynar®) transducer housing
PT-500 Series Submersible Pressure Transducers
PT-500 Series Submersible Pressure Transducers

Pressure Transducer for Liquid Depth Measurement

  • Depth or level measurement up to 450 ft.
  • Hazardous location approvals
  • Removable cage option for applications containing debris
  • Adjustable zero reference for 4-20 mA signal
  • Well depth, sea water, tank level, waste water, reservoir level
IRU-2002 Ultrasonic Sensor
IRU-2002 Ultrasonic Sensor

Programmable Solid-State Relay Output

  • 1 to 25 ft. (0.3 to 7.6 m) detection range
  • Thru-hole mounting for easy installation in monitoring & control applications
  • Potentiometer adjustment for relay activation point and sensitivity setting
  • Software adjustable filtering and response time using RST-3001 programming module (USB)
  • Solid state relay output has multiple logic functions available for process control
  • Internal temperature compensation
IRU-2003 Ultrasonic Sensor
IRU-2003 Ultrasonic Sensor

Isolated 4-20 mA Output

  • 1 to 25 ft. (0.3 to 7.6 m) detection range
  • Thru-hole mounting for easy installation in monitoring & control applications
  • Potentiometer adjustment for sensitivity setting
  • Software adjustable filtering and response time using RST-3001 programming module (USB)
  • Scalable analog output signal for measurement applications
  • 4-20mA circuit can be powered by a isolated source to eliminate potential ground loops
IRU-2004 Ultrasonic Sensor
IRU-2004 Ultrasonic Sensor

RS-485 with NPN Trip Point Output

  • 1 to 25 ft. (0.3 to 7.6 m) detection range
  • Thru-hole mounting for easy installation in monitoring & control applications
  • Programmable via RS-485
  • NPN transistor switch output provides automation control capabilities
  • Programmable filtering and response time
IRU-2005 Ultrasonic Sensor
IRU-2005 Ultrasonic Sensor

4-20 mA + Two NPN Trip Point Outputs

  • 1 to 25 ft. (0.3 to 7.6 m) detection range
  • Thru-hole mounting for easy installation in monitoring & control applications
  • Adjustable filtering and response time using RST-3001 programming module (USB)
  • Scalable analog output signal for measurement applications
  • Two NPN transistor switches for multiple control functions
  • Internal temperature compensation
DCU-1104 Ultrasonic Sensor
DCU-1104 Ultrasonic Sensor

Integrated Keypad & Display

  • 2 to 50 ft. (0.6 to 15.2 m) measurement range
  • 2 to 18-22 ft. detection range on granules & bulk solids
  • 4-20 mA + Two solid state relays
  • FM Class I, Div. 2 hazardous location approval
  • 3 in. NPT for easy mounting in tank level applications
  • Programmable filtering options & response time
FLE Series Custom Mini Multi-Point Float Switches
FLE Series Custom Mini Multi-Point Float Switches

Miniature Multi-Point Level Sensors

  • Customized to customer specifications
  • Mini size for small vessels
  • Up to three switch levels per sensor
  • Variety of mounting options available
  • Long switch life
FLR Series Custom Multi-Level Float Switches
FLR Series Custom Multi-Level Float Switches

Custom Multi-Point Float Level Sensor

  • Built to customer specifications
  • Up to seven floats on a single stem
  • Wide variety of mounting options
  • Field adjustable switch points (housing required)
  • Long switch life
FLX Series Custom Multi-Level Stem Floats for Hazardous Areas
FLX Series Custom Multi-Level Stem Floats for Hazardous Areas

Multi-Point Float Switch Level Sensors for Hazardous Areas

  • Built to customer specifications
  • Class I, Div I hazardous location approvals
  • Up to seven floats levels per sensor
  • Wide variety of mounting options
  • Long switch life
KA-2H Cable Suspended Float Switch
KA-2H Cable Suspended Float Switch

Discharge or Pump Down Switching Action

  • Hysteresis switch action for emptying or discharge
  • 10 in. to 50 in. switching differential
  • No external moving parts
  • Usable in most liquids
  • No mercury, no lead
  • Adjustable switching points (via cable weight)
  • Polypropylene body
  • Cost effective
KA-2L Cable Suspended Float Switch
KA-2L Cable Suspended Float Switch

Fill or Pump Up Switching Action

  • Hysteresis switch action for pumping up or filling applications
  • 10 in. to 50 in. switching differential
  • No external moving parts
  • Usable in most liquids
  • No mercury, no lead
  • Adjustable switching points (via cable weight)
  • Polypropylene body
  • No maintenance required
  • Cost effective