Performance
Available Ranges
1 to 25 ft.
5" to 12 ft.
Accuracy
±0.25% of detected range
Electrical
Operating Voltage
8-24 VDC
Total Current Draw
18-26 mA @ 24 VDC, Typ. 18 mA
32-63 mA @ 8 VDC, Typ. 37 mA
Waiting Status Current Draw
13 mA @ 24 VDC
17 mA @ 8 VDC
Gas Discharge Tube Surge Protection
150 V, 1 kA
Wiring Connection
4-Conductor Shielded Cable
M12 Micro Connector
(requires approved mating connector/cable)
Approvals
CSA Intrinsically Safe
Class 1, Div. 1, Groups C & D
Class 1 Zone 0, AEx ia IIB T4 Ga
ATEX
Ex II 1 G Ex ia IIB T4 Ga
IECEx
Ex ia IIB T4 Ga
Optional Gas Discharge Tube Surge Protection
Compliant with IEC 61000-4-5
Connectivity
Output
RS-485 Modbus RTU
Data Portals
Online
LAN
Programming
Method
Online Data Portal
Modbus Register
Physical
Upper Housing
PC/PBT blend
Transducer
Ceramic transducer, PVDF faced
Mounting
Sensor Face: 2 in. NPT
Sensor Back: 3/4 in. NPT
Environmental
Operating Temperature
Standard
-30 to 60° C (-22 to 140° F)
Alternate
-20 to 54° C (-4 to 122° F)
Housing Rating
IP68
M12 connector only rated to IP67
> !function(f,b,e,v,n,t,s) {if(f.fbq)return;n=f.fbq=function(){n.callMethod? n.callMethod.apply(n,arguments):n.queue.push(arguments)}; if(!f._fbq)f._fbq=n;n.push=n;n.loaded=!0;n.version='2.0'; n.queue=[];t=b.createElement(e);t.async=!0; t.src=v;s=b.getElementsByTagName(e)[0]; s.parentNode.insertBefore(t,s)}(window, document,'script', 'https://connect.facebook.net/en_US/fbevents.js'); fbq('init', '2241001876219184'); fbq('track', 'PageView');
> !function(f,b,e,v,n,t,s) {if(f.fbq)return;n=f.fbq=function(){n.callMethod? n.callMethod.apply(n,arguments):n.queue.push(arguments)}; if(!f._fbq)f._fbq=n;n.push=n;n.loaded=!0;n.version='2.0'; n.queue=[];t=b.createElement(e);t.async=!0; t.src=v;s=b.getElementsByTagName(e)[0]; s.parentNode.insertBefore(t,s)}(window, document,'script', 'https://connect.facebook.net/en_US/fbevents.js'); fbq('init', '2996670937328619'); fbq('track', 'PageView');